Finapres® Nova NC – all ECG hardware options

Choisissez votre Configuration

Finapres® Nova NC – all ECG hardware options

Finapres® Nova NC BASIC

ECG cable to add – FINGER + ARM BLOOD PRESSURE MEASUREMENT + analog inputs and outputs

Finapres® Nova NC ECG + RESP

BASIC ECG cable + ECG + RESPIRATION

Chargement de la configuration...

Product Reference:

NOVA+FOH

Accessories and Consumables

Our services to support you at every stage.

Beat-to-beat NIBP monitor designed for real-world demands

An advanced hemodynamic monitoring solution, non-invasive and scalable, designed to deliver complete, continuous real-time cardiovascular analysis.

Continuous non-invasive blood pressure measurement (finger and brachial)
Beat-to-beat analysis of hemodynamic parameters
Systolic, diastolic and mean blood pressure
Heart rate and inter-beat interval
Multi-lead ECG (3 or 5 leads) with advanced detection
Respiratory monitoring via thoracic impedance
SpO2 monitoring (Full Options version)
Dual finger cuff system for comfortable 24/7 monitoring
Scalable platform with modules and software added as needed

moniteur de signes vitaux

Real-time blood pressure waveforms

Scalable platform

with modules and software added as needed

Continuous hemodynamic analysis without invasive methods

Comprehensive multi-parameter overview

Scalable solution adaptable to clinical and research needs

Optimized patient comfort for prolonged recordings

Choose the configuration suited to your activity

  • Finapres® NOVA Full Options is the most comprehensive version, integrating all parameters (blood pressure, ECG, respiration, SpO2) for an overall, advanced hemodynamic analysis.
  • Finapres® NOVA Basic focuses on continuous blood pressure measurement using Finapres® technology proven for over 30 years.
  • Finapres® NOVA ECG + Resp adds an electrophysiological and respiratory dimension to blood pressure analysis for a more comprehensive assessment.

A benchmark technology in hemodynamic monitoring

Based on more than 30 years of research and widely used in leading clinical and scientific environments, Finapres® NOVA relies on proven continuous non-invasive measurement technology.

Its ability to provide beat-to-beat data in real-world conditions, without burdening the patient, makes it a unique tool for detailed analysis of cardiovascular variations, where traditional methods remain limited.

Get support from our experts at every stage of your project.

Your ready-to-use cardiology equipment

Integrate a complete, scalable hemodynamic monitoring solution that can adapt to your needs—from continuous blood pressure monitoring to advanced cardiovascular analysis—while ensuring accuracy, comfort, and data continuity.

From diagnosis to follow-up, we offer a complete solution bringing together reliable, compatible, and ready-to-use equipment.

Beyond products, we support you at every stage: purchasing advice, installation, preventive/corrective maintenance, and after-sales service.

Our expert advice

“Continuous hemodynamic monitoring provides access to detailed, dynamic analysis of cardiovascular parameters. With a solution such as Finapres® NOVA, you gain a comprehensive view of the patient—essential for refining clinical decisions in the most demanding situations.”

Régis Andrieu

Director of Cardiology

Technical specifications
Measurement typeContinuous non-invasive blood pressure (finger and brachial)
TechnologyFinapres® (beat-to-beat measurement)
MonitoringContinuous 24/7
Measured parametersSBP, DBP, MAP, heart rate, RR interval
ECG3 or 5 leads (depending on configuration)
RespirationThoracic impedance (depending on version)
SpO2Yes (Full Options version)
Sensor typeDual finger cuff
CalibrationReal-time pressure waveforms
ConnectivityData transfer to PC
System architectureBased on Windows 10
ScalabilityExpandable hardware and software modules

Useful resources

Need more details? Consult the documents below.

Share this product sheet

Send an email to the person(s) of your choice who may be interested in this equipment. A personalized email will allow your correspondent to directly access this product’s information.

Share Product Details

"*" indicates required fields

List of people you would like to share this information with:

Share this product sheet

Send an email to the person(s) of your choice who may be interested in this equipment. A personalized email will allow your correspondent to directly access this product’s information.

Share Product Details

"*" indicates required fields

List of people you would like to share this information with:

What are you looking for?

You are entering the Cardiology Area of the Spengler Medical group. This site is reserved for healthcare professionals.

In accordance with Law No. 2011-2012 of December 29, 2011 on the strengthening of health safety of medicines and health products, I certify that I am a Healthcare Professional or equivalent in order to access the product information on this site.
By continuing your navigation, you certify on your honor that you are a Healthcare Professional or equivalent.